Skip to main content
← All vulnerabilities
CVE-2011-20002

A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl.

Published
Last modified
published
Not listed in CISA KEV
Fix
Fixed in V2.0.2
None on Exploit-DB, Metasploit or GitHub
  • Exploitation: none
  • Automatable: no
  • Technical impact: partial

Summary

A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.

Timeline

  1. CVE published
  2. CISA SSVC assessment

    Exploitation: none · Automatable: no · Technical impact: partial

  3. Record last updated

Affected versions

  • Siemens SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants)

    fixed in V2.0.2

  • Siemens SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants)

    fixed in V2.0.2

References 1

cert-portal.siemens.com